This page documents the wire-level protocol the engine and SDK workers exchange. Most projects use a language SDK (Node, Python, Rust, Browser) and never touch the protocol directly. The shapes below are the source of truth those SDKs serialize to.
Observability introspection (traces, logs, metrics, sampling rules, alerts, rollups) is owned end-to-end by the iii-observability worker. The engine injects this worker automatically; do not declare it in config.yaml, engine.workers, or containers.

Connection ports

The engine binds its worker and stream WebSockets. Project HTTP routes and observability use their own workers: The console UI (ADE) runs on 3113 by default. Add it to a project with iii trigger compose::add worker=ade.

Connection flow

A worker opens the SDK WebSocket (default ws://127.0.0.1:49134). On connect the engine assigns the worker a UUID and sends a WorkerRegistered { worker_id, reattach_token, features } frame carrying it. The worker sends the registrations it holds in memory (each RegisterFunction, RegisterTrigger, and RegisterTriggerType it intends to expose, then each Observe it owns) and calls engine::workers::register to publish its own metadata (runtime, version, OS, PID, isolation, optional namespace, an optional one-line description, and the protocol features it supports), which the engine acknowledges with a RegisterWorkerResult. See Feature negotiation for what features turns on. The engine answers every request on the worker listener (/, /otel, /ws/channels/{id}), including the WebSocket upgrade, with an x-iii-capabilities response header: optional transport capabilities as comma-separated tokens. Clients ignore tokens they do not know. tcp-nodelay means the engine’s end of the socket has TCP_NODELAY set, so the worker may disable Nagle on its end too. A worker must not disable Nagle without this token: with Nagle on the engine’s end only, a worker that answers immediately leaves the engine’s next small frame waiting for the worker’s delayed ACK (~40 ms on Linux), which is slower than keeping Nagle on both ends. Older engines send no header. The connection is bidirectional from that point on: the engine pushes InvokeFunction frames at the worker, and the worker pushes InvocationResult, additional registrations, or unregistrations back. A connection gets its namespace from the engine::workers::register call. A client can send registration messages before this call. The engine holds these messages until it knows the namespace. It does not register them in default and move them later. When engine::workers::register arrives, the engine registers the worker, sets the connection namespace, and processes the held messages in arrival order. If the registration timeout expires first, the engine sets the connection namespace to default. See Namespaces.

Feature negotiation

Observers and local dispatch (0.25) are negotiated per connection, so a 0.24 SDK keeps working against a 0.25 engine, and a 0.25 SDK against a 0.24 engine.
  • Engine to worker. WorkerRegistered carries features. A 0.25 engine sends ["observe.v1", "local-dispatch.v1"]; older engines omit the field.
  • Worker to engine. The worker lists the features it supports in the features array of its engine::workers::register payload. A pre-0.25 SDK sends none. Besides the two above, a worker can declare large-messages.v1, which the engine never advertises (see the rules below).
Rules:
  • The first engine::workers::register that carries a non-empty features list fixes the connection’s features. Later declarations are ignored (logged at debug). The engine keeps at most 32 names, and drops names longer than 64 bytes. A malformed list costs the worker its features, never its registration.
  • The engine pushes FunctionRegistered, ObserverAdded, and ObserverRemoved only to connections that declared observe.v1. ObserveResult and ObserverStateChanged answer a connection’s own Observe and go to it regardless. Old SDKs never receive a message type they cannot decode.
  • The engine adds caller, observe_depth, and activation to an InvokeFunction only when the receiving connection declared observe.v1.
  • The engine decodes every worker-to-engine observe message from any connection.
  • large-messages.v1 commits the connection to receiving JSON messages up to 64 MiB (67,108,864 bytes of serialized envelope), sent as one WebSocket text frame or as a fragmented message. The engine then sends it messages up to that size whatever version it reports, except to runtime: "browser" (16 MiB). Without it, the engine falls back to the reported SDK version; no other feature counts. The Rust, Node, Python, and Go SDKs declare it from 0.25.0; the browser SDK does not. See Payload size.
  • An SDK enables observe() only when the engine advertised observe.v1; against an older engine, observe() fails with UNSUPPORTED. An SDK runs one of its own functions in-process only after the engine confirmed that function with FunctionRegistered { local_dispatch: true }.
  • If the namespace grace timer drains before engine::workers::register arrives, the connection is treated as legacy until it does; the engine then sends FunctionRegistered for the functions the connection already registered.

Message types

Every frame is a JSON object discriminated by type (the lowercased variant name, e.g. registerfunction). The full set, defined on Message in engine/src/protocol.rs:
The trigger messages (RegisterTrigger, UnregisterTrigger, TriggerRegistrationResult, RegisterTriggerType, UnregisterTriggerType) are deprecated in 0.25. They keep working in this release and will be removed in a future one. New providers register a function with an observe descriptor, and new consumers send Observe. See Upgrading from 0.24.x.

RegisterFunction

id is required. description, request_format, response_format, and metadata are optional and feed the iii console and the agent-readable skills. invocation is reserved for external HTTP functions (HttpInvocationRef); leave it out (or null) for in-process handlers. Since 0.25 the engine omits request_format and response_format when it sends a registration that has none, instead of writing null.

observe descriptor

Every function is observable. A function that wants to say how its observers are delivered adds an optional observe object (0.25). The SDK-local callbacks (onObserverAdded, onObserverRemoved) never travel; only these four fields do. The example’s cron::on-tick is illustrative: the cron worker still publishes the cron trigger type in 0.25.
A function without observe is observable with delivery: auto and accepts no args. The engine answers a descriptor with args_format and delivery: auto, or with an unknown delivery value, with RegistrationRejected { code: "INVALID_OBSERVE_DESCRIPTOR", function_id } and does not register the function. See Observable functions for the provider side. When the registration is accepted, a connection that declared observe.v1 receives FunctionRegistered.

RegisterTrigger

Deprecated in 0.25: use Observe instead. RegisterTrigger keeps working through a live trigger-type provider, or through the legacy shim once the provider moved to a function. See Upgrading from 0.24.x.
config is the per-trigger-type configuration; the shape is defined by whatever worker advertised that trigger_type (e.g. http for http triggers). The engine responds with a TriggerRegistrationResult carrying an optional error: ErrorBody. namespace specifies the namespace of the target function. It uses the same namespace system as worker registration. Usually, it has the same value as the worker namespace. A trigger can call a function in a different namespace. For this reason, RegisterTrigger includes the target namespace. If this field is not present, function_id resolves in default. A present field must be a non-empty string; the engine rejects null and any other non-string value. trigger_namespace specifies where to find the trigger type’s provider. It is a different question from namespace: one locates the target function, the other locates the provider that fires it. If trigger_namespace is not present, the engine resolves it in two steps: the registering connection’s namespace first, then default. This is not the same as sending "default". The two steps let a project register its own provider for a trigger type id that the engine also provides, while a worker that names nothing still reaches the engine’s provider. If trigger_namespace is present, resolution is strict: that namespace or nothing. A binding that names a namespace is never moved to another provider. When a provider registers in a namespace after a binding already resolved to default, the engine moves that binding to the new provider. Start order does not decide which provider serves a project. These fields target math::add in default:
These fields target math::add in orders:

RegisterTriggerType

Deprecated in 0.25: register a function with an observe descriptor instead. RegisterTriggerType keeps working in this release. See Upgrading from 0.24.x.
trigger_request_format is the JSON Schema for the trigger’s per-binding config. call_request_format is the JSON Schema for the payload delivered to bound functions when the trigger fires. namespace is the namespace this provider serves. If it is not present, the engine files the provider under the registering connection’s namespace. Providers are keyed by (namespace, trigger_type_id), so two workers in different namespaces can advertise the same trigger_type id without replacing each other. The engine’s own providers (http, cron, state, stream) register in default.

UnregisterTriggerType

Every SDK has always sent this frame when a provider retires a trigger type, but engines before 0.25 did not decode it and dropped it with a decode warning. A 0.25 engine handles it: it removes the trigger type when the sending connection is its provider, and ignores the frame (with a debug log) otherwise. Bindings of that type then move to a fallback provider, are taken by a function that declares the type as its legacy_trigger_type (see Legacy shim), or stay stored, unserved, until a provider returns. namespace is optional and names the namespace the provider was filed under. If it is not present, the engine uses the sending connection’s namespace, as for RegisterTriggerType. Like the other trigger messages, UnregisterTriggerType is deprecated.

InvokeFunction

invocation_id is omitted on Void invocations (the worker has no result channel to reply on). The optional metadata field on a trigger registration (null / None in the examples above) is arbitrary JSON stored with the trigger and delivered to the receiving function as a distinct argument alongside the payload. It is useful for providing contextual information about the trigger or execution context to the receiving function. A target function shared by many triggers can use it to recover which registration fired and with what context. metadata can be provided both via registerTrigger and direct trigger() invocations. traceparent and baggage contain W3C trace context. action is the routing flag (see Trigger actions below); absent / null means synchronous. namespace is optional and selects the namespace function_id resolves in. Omit the field to resolve in default; omission also keeps a peer that never sends it wire compatible. Send a non-empty string when the field is present. The engine rejects null and any other non-string value. See Namespaces for the resolution rules.

Observe fields

0.25 adds three optional fields. Their meaning depends on the direction: The engine adds these fields to a frame it sends only when the receiving connection declared observe.v1. It reads them leniently: a malformed value counts as absent instead of failing the call. caller.parent is one level only; a parent inside parent is not part of the format and the engine drops it. caller.worker_* cannot be forged; function_id, invocation_id, and parent are asserted by the calling SDK and are useful for routing and filtering, not for authorization. The engine still injects _caller_worker_id into data in this release. A routed call, as the engine forwards it:
Activations. When an observer fires, the engine invokes its target with an ordinary InvokeFunction. data is the Observed envelope (or the observed input / output, per the observer’s deliver), metadata is the observer’s metadata sidecar, and caller is the engine (worker_name: "iii-engine", with the observed function and invocation). An activation carries an invocation_id and no action: the target’s SDK answers it with an InvocationResult like any call. For auto and obs.emit activations the engine discards the result; the answer frees the observer’s max_in_flight slot, and so does observers.activation_timeout_ms (30 s by default) for an activation never answered. The observed input never contains the engine’s _caller_worker_id stamp.
Owner delivery (obs.call). The owner of an owner-delivered function sends an InvokeFunction to the observer’s target with activation: { observer_id }, and gets the target’s result back as an ordinary InvocationResult. The SDK sends no namespace: the engine routes the call to the observer’s stored target and ignores a namespace if one is present. The engine checks, in order:
  1. The observer exists, else OBSERVER_NOT_FOUND.
  2. The sender is the current owner of the observed function, else NOT_FUNCTION_OWNER.
  3. The observed function has delivery: owner, else NOT_OWNER_DELIVERED.
  4. The observer is active, else OBSERVER_NOT_ACTIVE.
  5. function_id equals the observer’s target, else TARGET_MISMATCH.
  6. Policy: depth (LOOP_GUARD), expiry, max_fires, then max_in_flight (OVERFLOW; an owner delivery over the limit fails instead of queueing, because the owner waits for the result).
It then adds the observer’s metadata, an activation_id, and observe_depth + 1, and routes the call. A failed check comes back as the InvocationResult.error of that call; a target that does not answer within observers.activation_timeout_ms fails with TIMEOUT.

InvocationResult

Success:
Failure:
ErrorBody.code values that appear in InvocationResult.error include invocation_failed (handler threw), invocation_stopped (the owning worker disconnected mid-flight, so the engine cancels the in-flight call and surfaces this code to the caller), function_not_found, function_not_invokable, TIMEOUT (client-side timeout), FORBIDDEN (RBAC denial). A function_not_found message names the namespace the lookup ran in, and lists the namespaces where the id does exist: Function state::get not found in namespace default. It is registered in namespace(s): orders, analytics.

RegistrationRejected

The engine sends this message when a registration conflicts with a live worker in namespace. owner_worker_id identifies the worker that owns the identity. code specifies the identity field and the severity. Each message contains only one identity field: A function conflict has this format:

Function conflict behavior

Worker registration and function registration are separate operations. The engine can accept a worker and reject one of its functions. For a function ownership conflict, the engine:
  1. Keeps the current function owner.
  2. Does not register the new handler.
  3. Sends FUNCTION_NAMESPACE_CONFLICT to the new worker.
  4. Keeps the new worker connection open.
  5. Continues to register and serve the new worker’s other functions.
FUNCTION_NAMESPACE_CONFLICT is a registration result. It is not an invocation result. A later invocation of the same function id in the same namespace goes to the current owner. It does not go to the worker whose registration was rejected.
A connected worker does not confirm that all its functions are registered. The SDK reports a function conflict as a warning and keeps the worker active. If the worker requires all its functions, treat this warning as a startup or deployment error.
A worker restarting against its own not-yet-cleaned connection is not a conflict: the engine treats a connection that has begun tearing down as not live, so the restart reclaims its name immediately.

Trigger actions

InvokeFunction.action is tagged by type and lowercase-encoded on the wire:

Invocation lifecycle

For synchronous calls the engine assigns an invocation_id, forwards the InvokeFunction to the owning worker, and waits for the matching InvocationResult. For Void actions the engine forwards without an invocation_id and never expects a reply. For Enqueue the engine hands the invocation to the queue worker, which persists it and re-invokes the target function on a subscriber according to the queue’s retry policy.

Observe messages

0.25 makes every function observable. An observer is what iii.observe(source, target, options) creates: a source function with its args and filters, a target function, and a policy. The observing worker is the connection that sent Observe; the owner is the connection that hosts the observed function. For the model, see Observers; for the provider side, see Observable functions; for the filter language, see Filters.
The wire examples on this page use cron::on-tick, http::on-request, and database::on-row-changed as illustrative source functions. The cron, http, and database workers have not migrated in 0.25 and still publish trigger types.

Wire rules

  • Optional means absent. An optional field that is not set is left out, never sent as null. Decoders accept null for it anyway. In InvocationsObserved items, input, output, error, and metadata keep null apart from absent: "output": null is a function that returned null.
  • Enums are lowercase strings. delivery: auto | owner. capture[]: input | output | error | caller | metadata. on: success | error | complete. deliver: envelope | input | output. state: pending | active | suspended | error | disposed. status: success | error. A decoder keeps a value it does not know instead of failing the frame.
  • Defaults. Absent on is success, absent capture is ["input", "output", "caller"], absent deliver is envelope, absent observe.delivery is auto, absent observe.allow is true, and absent observe_depth is 0 (0 is omitted when sending). capture: [] is valid: the target then gets ids, status, and timings only.
  • Unknown values are refused, never defaulted. An Observe with an unknown on, deliver, or capture[] value gets ObserveResult with error UNSUPPORTED (the message names the field). A RegisterFunction with an unknown observe.delivery gets RegistrationRejected INVALID_OBSERVE_DESCRIPTOR.
  • Ids are strings. Observer ids are client-generated UUID v4 strings, stable across replays.
  • Malformed frames. An Observe the engine cannot decode but whose id is a string gets ObserveResult with error INVALID_ARGS.
  • Revisions. revision counts adds and removes per (namespace, function_id) and grows by one on each. An SDK ignores an ObserverAdded or ObserverRemoved whose revision is not greater than the one it holds on the same connection. FunctionRegistered is always accepted and replaces the set (revisions restart after an engine restart).
  • Normal form. The filters the engine pushes to an owner are the observer’s filters in normal form: {} matches every event, anything else is {"$and": [...]} at every level. Compile them as given. See Filters.
  • What owners see. An owner receives an observer’s id, args ({} when none), normalized filters, target function id (its namespace is not disclosed), capture, on, and legacy when set. It never receives deliver, the observer’s metadata, its policy, or the observing worker.

Observe

Observing worker -> engine. Creates an observer owned by the sending connection, or replays it idempotently (same id, same spec).
The minimal form names only the two functions:
At creation the engine checks RBAC (the session must be allowed to invoke both the observed function and the target, and the on_observer_registration_function_id hook may rewrite or deny), args, filters (including filter paths against the function’s request_format / response_format), the per-connection and per-function limits, and that the target is not the observed function (SELF_TARGET). A replay with the same id and a different spec fails with OBSERVER_ID_CONFLICT.

Unobserve

Observing worker -> engine. Disposes an observer this connection owns.

ObserveResult

Engine -> observing worker. The reply to Observe (also to a replay): the observer’s current state.
A rejected observer carries state: error and the error. warnings lists filter paths the engine could not verify against the function’s schemas (an open schema, a remote $ref, several anyOf branches):

ObserverStateChanged

Engine -> observing worker. Every lifecycle transition. fires is always sent; reason explains error, suspended, and disposed states.
States:

FunctionRegistered

Engine -> owner (only to connections that declared observe.v1). The success ack RegisterFunction never had, sent once per registration and again after a re-registration. It carries the function’s full current observer set and whether the SDK may run the function in-process.
  • observers is sent even when empty.
  • local_dispatch is true when the engine’s observers.local_dispatch is on, the session has no RBAC middleware, and the connection may invoke the function itself. Only then may the SDK run its own calls to the function in-process.
  • The owner must ack every observer listed, each with this message’s revision, including the ones it already held before a re-registration: a new registration starts a new owner relationship. Until it is acked an observer stays pending; after observers.owner_ack_timeout_ms (30 s by default) it fails with OWNER_TIMEOUT.

ObserverAdded

Engine -> owner (only to connections that declared observe.v1). One observer attached to a function this connection hosts. It waits for an ObserverAck.
The engine always sends capture and on resolved. observer.legacy is present only for an observer made by the legacy shim.

ObserverRemoved

Engine -> owner (only to connections that declared observe.v1). One observer detached: Unobserve, disposal, the observing worker’s grace period elapsed, or a late rejection.

ObserverAck

Owner -> engine. Accepts one announced observer, echoing function_id, namespace, id, and the revision of the message that announced it (ObserverAdded, or FunctionRegistered). The SDK sends it after the owner’s onObserverAdded callback returns, so whatever the owner indexed there is in place before the engine marks the observer active.
With error, the ack rejects the observer, which turns error with that reason. The code is the owner’s own (here INVALID_CRON_EXPRESSION), OBSERVE_REJECTED when the callback threw a plain error, or OWNER_TIMEOUT:
  • namespace is optional; absent means the sending connection’s namespace.
  • An ack whose revision is older than the announcement is ignored as stale.
  • Late rejection. An owner may send an ack with error for an observer that is already active (for example after a configuration reload removed what it observed). The engine moves the observer to error and sends ObserverRemoved back to the owner.
  • The owner never changes an observer’s filters.

InvocationsObserved

Owner -> engine. Batched reports: matched local invocations of auto functions (the SDK evaluated the filters), and obs.emit events of owner-delivered functions (the owner picked the observers, the SDK applied their filters). SDKs flush at 256 items or after 5 ms, whichever comes first, and split a flush to stay under the 16 MiB frame limit.
The engine checks the items one by one:
  • The reporting connection must be the current owner of the function, else the item is dropped as REPORTER_NOT_OWNER.
  • An item that does not decode, or whose status is neither success nor error, is dropped alone (counted as INVALID_REPORT), and the rest of the batch is applied.
  • matched ids that are not active observers of that function are dropped as INACTIVE.
  • The engine does not re-evaluate filters on reports: the owner is authoritative for its own function’s data. on is not checked for owner-delivered functions.
Reports have backpressure. When an item finds an observer’s queue full (OVERFLOW), the engine stops reading from the reporting connection until that queue is back to half of observers.max_queue_per_observer and the queues together are under half of their 64 MiB, the observer leaves active, or 250 ms pass. A worker that reports faster than the targets take is slowed by its own socket, and its SDK drops the excess from its bounded report buffer (BUFFER_FULL), so the engine does not spend its CPU decoding reports it would drop. Everything else the worker sends waits behind the report meanwhile, so the holds are paced: after holding a connection, the engine reads it for at least a quarter as long before it may hold it again, and drops the items that overflow meanwhile (OVERFLOW). A connection is held at most 250 ms at a time and at most four fifths of the time, however long its reports keep overflowing. The engine does not wait for an observer whose target the reporting connection hosts: the answers that would free the queue come in on that connection.

LocalInvocationStats

Owner -> engine. Every 10 s, only when non-zero: per-function counts of local invocations (which feed the engine’s invocation metrics) and SDK-side report drops.
functions[].errors and functions[].duration_ms_sum default to 0; both arrays default to empty. The engine ignores entries for functions the connection does not own. dropped_reports[].reason is BUFFER_FULL or TOO_LARGE; any other reason is counted as OTHER.

Legacy shim

A provider can move from a trigger type to a function without breaking workers that still send RegisterTrigger. The function declares observe.legacy_trigger_type with the trigger type it replaces. When a RegisterTrigger names a type with no live old-style provider, and a function declares that type (looked up in the trigger’s trigger_namespace only when it names one, otherwise in the registering connection’s namespace, then default), the engine:
  1. Creates an observer on that function, owned by the registering connection: the trigger id becomes the observer id, with no args or filters, deliver: input (so the target receives what a trigger handler received), the trigger’s metadata as the metadata sidecar, and legacy: { trigger_type, config }.
  2. Sends ObserverAdded to the owner with observer.legacy:
  3. The owner validates legacy.config as its trigger handler did, reads it as the observer’s args, and acks or rejects it like any observer. The engine skips args_format validation for it.
  4. The registrant gets one TriggerRegistrationResult with the outcome: a success once the owner acked (SDKs ignore it), or the owner’s error if it rejected.
  5. UnregisterTrigger (or engine::unregister_trigger) disposes the observer.
A live old-style provider always wins for new registrations: the shim is a fallback, and the observers it made stay where they are when such a provider registers later. A new RegisterTrigger with the same id replaces the observer, as it replaces a trigger. Only an owner that declared observe.v1 stands in for a trigger type; legacy_trigger_type on any other owner is ignored. Bindings stored while no provider existed convert when a stand-in registers. When the owner leaves, its legacy observers wait and are replayed like any other observer.

Error codes

ObserveResult.error.code and ObserverStateChanged.reason.code on a rejected observer: Owner delivery (obs.call) fails with OBSERVER_NOT_FOUND, NOT_FUNCTION_OWNER, NOT_OWNER_DELIVERED, OBSERVER_NOT_ACTIVE, TARGET_MISMATCH, LOOP_GUARD, OVERFLOW, TIMEOUT, or the target’s own error. SDK-side, obs.call fails with FILTERS_NOT_MATCHED (the observer’s filters reject the payload; nothing is sent), NOT_OWNER_DELIVERED (obs.emit or obs.call on an auto function), or OBSERVER_NOT_ACTIVE. State reasons (ObserverStateChanged.reason.code): Drop reasons, counted per observed function in iii.observer.dropped.total (never silent; the metric is updated once a second):

Namespaces

A namespace is a routing value carried with a function id. It is not part of the function name. For example, state::get has the same id in every namespace. Registries are keyed by (namespace, function_id) and (namespace, worker_name), so the same id or worker name may appear once per namespace. A worker declares its namespace on the engine::workers::register call (RegisterWorkerInput.namespace). A connection that declares none lands in default.

Resolution

Invocation routing is strict. It never falls back to another namespace: The SDKs fill the field from the worker namespace when the caller sets none on the invocation, so the frame carries the worker’s own namespace, or default when the worker declared none. A miss returns function_not_found naming the namespaces where the id does exist. Introspection resolution is deliberately looser, so that an engine whose every worker is namespaced can still answer questions about itself. For engine::functions::info and engine::workers::info with no explicit namespace: a default entry wins; otherwise an id or name unique to one non-default namespace resolves; an id or name present in several non-default namespaces at once is reported as an ambiguity naming the candidates, never resolved by guessing. Passing an explicit namespace restores strict resolution.

Reserved ids

engine::* is reserved for engine infrastructure, which is registered in default. A custom worker that tries to register an engine::* function id in another namespace has that registration refused. The queue worker supplied with the engine registers its engine::queue::* functions in default. The reserved-id check does not reject these functions.

Wire compatibility

Every namespace field is optional and omitted when unset. A worker built against an older SDK sends no namespace, lands in default, and behaves exactly as before. An explicit null is not the same as an absent field: the engine rejects it, as it rejects any non-string value.

Engine discovery functions

The engine registers a set of functions under the engine::* prefix for introspection and worker lifecycle. Defined in engine/src/workers/engine_fn/mod.rs: Every row returned by engine::functions::list, engine::functions::info, engine::workers::list, and engine::workers::info carries a namespace field naming the registry key under which the entry is registered. It distinguishes two rows that share a function_id or a worker name. Neither list function takes a namespace filter; both return every namespace.

Engine discovery triggers

In 0.25 these trigger types keep firing, and the engine also hosts an event-source function for each. Observe the function instead of registering a trigger, with deliver: "input" (the events have no output): Both live in default. Calling them directly fails with FORBIDDEN: their events are the engine’s to emit. See Engine-hosted event sources.

Engine-collected metrics

These metrics are emitted by the engine regardless of which language SDK a worker uses. Names and units come from engine/src/workers/observability/metrics.rs.

Invocations

Since 0.25 a worker runs calls to its own functions in-process (local dispatch), so the engine does not route them. SDKs report their counts in LocalInvocationStats, and the engine adds them to iii.invocations.total with the labels function_id, status (ok or error), and dispatch="local". Local invocations have no engine-side iii.invocation.duration sample.

Observers

Labelled per observed function, not per observer, to bound cardinality.

Workers

Per-worker